Measurements
Volt Output
Range 0.0 to 270 Volts
Resolution 0.1 Volt
Accuracy ±10 Digits of Resolution
Temperature Coefficient ±0.05 Volts per Degree C.
Phase Angle
Range 0 to 360 degrees
Resolution 0.1 degree
Accuracy ±1 degree
Frequency
Range 47 Hz to 66 Hz
Resolution 0.01 Hz
Accuracy ±0.02 Hz
Current Output
Range 20.1-200A, 2.01-20A, 0.02-2A
Resolution 0.1A, 0.01A or 0.001A
Accuracy ±10 Digits of Resolution
Temperature Coefficient ±0.016% of full scale current per Degree C.
Power
Range 0.0 to 5.4kW or 54kW
Resolution 0.001kW or 0.01kW
Accuracy ±10 Digits of Resolution
Temperature Coefficient ±0.06% of full scale per Degree C.
General
Line Input
47 Hz to 440 Hz
187 V - 252 V, L-L, 3ø
342 V - 456 V, L-L, 3ø with -UP option
Protection
Overcurrent, Overpower, Short circuit, Over voltage, Sense Line Fault, Digital Controller,
Shuts down system, Over-temperature, All units have adjustable Current Limit, on Voltage Output
Control
Front Panel Controls Circuit Breaker
Keypad 959XP Type
Bus IEEE-488.1
Subsets SH1, AH1, T6, L3, SR1, R12, DC1, DT1
Data Transfer Rate 200 K Bytes/sec.
Language Abbreviated Plain English (APE)
Front Panel Indicators
Power, Over temperature, Overload, High Range, Analog Volt Meter, Input Circuit Breaker
Connectors
Input provided on rear terminal block (TB-1)
Output provided on rear terminal block (TB-2) (voltage & low output current)
Bus Bars (high output current)
Note: Remote Sense Mating Connectors are provided
Mechanical
Height 10.5 In. (26.7 cm)
Width 19 In. (48.3 cm)
Depth 23 In. (58.4 cm)
Weight 165 Lbs (75 kg)
New Expanded AC Product Line Featuring California Instruments
   
AC Electronic Loads
AC Modular Supply
Discontinued Products
Product Support
Contact Sales
   
Service Agreement for all California Instruments AC except MX & FCS
4500 FX General Specifications
Specification Voltage Output High Current Output Low Current Output
Ranges Standard 0-270 V. All voltages
are L-N. For other voltage ranges, please contact Factory.
Standard: 20.1 - 200 Amps. All
current levels are rms.
Standard: 0.020 - 20 Amps. All
current levels are rms.
Accuracy TRMS Sense: ±0.135V from 5
V to 135V. ±0.54V from 135V to
270V. All at 25°C±1°C (Based
on TRMS reading)
Calibrates to ±0.02 Amps at
five cardinal points within
range.
a) Calibrates to ±0.002 Amps
on 2-20 Amp range (5pts)
b) Calibrates to ±0.0002 Amps
on 0.02-2 Amps range (6 pts)
Load Regulation TRMS Sense: ±0.05% FS,
no load to full load.
±0.05% FS ±0.05% FS
Line Regulation ±0.02% FS for ±10% line change
±0.05% FS ±0.05% FS
Stability (Amplitude) ±0.04 Volts per 24 hours. ±0.015% FS per 1000 hours at
constant line and load; 25°C.
±0.05% of range per 24 hours.
Default Values 5.0 volts (field selectable) N/A - Output Shorted 0.2 A Output Shorted
Frequency Range 47 Hz to 66 Hz 45 Hz to 66 Hz 45 Hz to 66 Hz
Frequency Resolution 0.01 Hz 0.01 Hz 0.01 Hz
Frequency Accuracy (25°C ±1°C) ±0.001% of programmed
value
±0.001% of programmed
value
±0.001% of programmed
value
Default Frequency  (Initial Value) Customer selectable
(within range)
Customer selectable
(within range)
Customer selectable
(within range)
Compliance Voltage N/A 0-7.5 V Operating 20.1-200
Amps
0-25V Operating 2-20 Amps
0-200V Operating 0.02-20
Amps
Total Power (RMS)
Output:**
1500 VA 1500 VA 400 VA at 2 Amps
500 VA at 20 Amps
Phase Accuracy ±1° ±1° ±1°
Phase Angle Programming 0 to ±999.9 degrees in 0.35
degree increments
High/Low current output
relative to Voltage output: 0 to
±999.9 degrees in 0.35
degree increments
High/Low current output
relative to Voltage output: 0 to
±999.9 degrees in 0.35
degree increments
Current Limit Adjustable Trip Setting N/A N/A
Harmonic Distortion
(to 30 kHz)
< 1% (with Linear Load)
0.5% Typical
1.5% Max. (with Linear Load)
0.8% Typical
1.5% Max. (with Linear Load)
0.8% Typical
* Accuracy is specified from 10% of Full Scale to Full Scale Output.